+8613271592250 amywanggood@hotmail.com

Blog

FB_IMG_1588031168414

Submersible PUMPS electrical cable copper wire conductor 450/750V

DRINCABLE

FEATURES & PROPERTIES :

Meets the requirement of CENELEC HD 22.1.S2, DIN   VDE 0282 PART     810, IEC 245,     CEI 20-19 & BS 6007,   BS 6899.

Designed for heavy duty use.

Non toxic cable.

Cur, tear & abrasion resistant.

Exceptional long term performance.

Excellent resistant to oils, chemicals,

ozone, solvents.

Excellent Impact Resistant.

Excellent Weather Resistant.

Performs & Looks like Vulcanize Rubber.

Excellent Electrical Properties.

 

APPLICATION :

Cables for drinking water.

CONSTRUCTION :

Conductor : Finely stranded bare copper flexible conductor.

Insulation : Water resistant EPDM base rubber,

Sheath : Black heavy duty EPDM base rubber.

Core Colours :

4core: Black, Light Blue, Brown, Yellow with green line Or Green with yellow line

4core: Red , Yellow Blue, Green Or Black

3CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Conductor PVC Insulation PVC Sheath Conductor Resistance at 20℃ (max)
Nominal Area No. & Dia. of wire Nominal Thickness Nominal Core Dia. Nominal Thickness Approx. Overall Dia
1.5 22/0.30 0.8 3.25 1.5 10 12.1
2.5 36/0.30 0.9 3.84 1.5 11 7.41
4 56/0.30 1 4.5 1.6 13 4.95
6 85/0.30 1 5.3 1.6 14.6 3.3
10 140/0.30 1 6.5 2 18 1.91
16 226/0.30 1 8 2 21.2 1.21
25 354/0.30 1.2 10.1 2.15 26 0.78
35 495/0.30 1.2 11.3 2.15 28.3 0.554
50 703/0.30 1.4 13.6 2.25 33.5 0.386
70 440/0.45 1.4 15.3 2.45 37.8 0.272
95 475/0.50 1.6 18 2.4 43.5 0.206

 

Read More
3core 5

Best popular 3KW 5KW 7KW 11KW 15KW solar water submersible pump cable

FEATURES & PROPERTIES :

Meets the requirement of CENELEC HD 22.1.S2, DIN

VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007, BS 6899.

Designed for heavy duty use.

Cur, tear & abrasion resistant.

Exceptional long term performance.

Excellent resistant to oils, acids, chemicals,

ozone & solvents.

Excellent Impact Resistant.

Excellent Weather Resistant.

Performs & Looks like Vulcanize Rubber.

Excellent Electrical Properties.

 

APPLICATION :

For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.

 

CONSTRUCTION :

Conductor : Finely stranded bare copper flexible conductor.

Insulation : Oil & water resistant thermoplastic rubber,

Sheath : Black heavy duty thermoplastic rubber.

Core Colours :

4core: Red, Yellow, Blue, Green Or Black

4core: Black, Light Blue, Brown, Yellow with green line Or Green with yellow line

 

4CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Conductor  Insulation Sheath Current

Rating at 40℃

Nominal Area No. &

Dia. of wire

Nominal Thickness Nominal

 

Core Dia.

Nominal

Thickness

Approx.

Overall

Dimensions

Thickness Width
mm2 No./mm mm mm mm mm mm Amps.
1.5 22/0.30 0.8 3.25 1.3 6 15.8 14
2.5 36/0.30 0.9 3.84 1.3 6.5 18 18
4 56/0.30 1 4.5 1.45 7.6 21 26
6 85/0.30 1 5.3 1.5 7.9 24.3 31
10 140/0.30 1 6.5 1.8 9.9 29.7 42
16 226/0.30 1 8 1.95 11.8 36 57
25 354/0.30 1.2 10.1 2 14.7 45.1 72
35 495/0.30 1.2 11.5 2 16.2 50.1 90
50 703/0.30 1.4 13.6 2.2 18.3 58.1 115
70 440/0.45 1.4 15.3 2.2 20 66.5 143
95 475/0.50 1.6 18 2.4 23.5 77.3 165

 

Read More
FB_IMG_1588031164784

Round pure copper cable for submersible water pumps 450/750V

FEATURES & PROPERTIES :

Meets the requirement of CENELEC HD 22.1.S2, DIN

VDE 0282 PART 810, IEC 245, CEI 20-19 & BS 6007,  BS 6899.

Designed for heavy duty use.

Cur, tear & abrasion resistant.

Exceptional long term performance.

Excellent resistant to oils, chemicals,

ozone & solvents.

Excellent Impact Resistant.

Excellent Weather Resistant.

Performs & Looks like Vulcanize Rubber.

Excellent Electrical Properties.

 

 

APPLICATION :

For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.

 

CONSTRUCTION :

Conductor : Finely stranded bare copper flexible conductor.

Insulation : Oil & water resistant thermoplastic rubber,

Sheath : Black heavy duty thermoplastic rubber.

Core Colours :

3core: Red ,Yellow and Blue.

3core: Black ,Light Blue and Brown.

 

3CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Conductor PVC Insulation PVC Sheath Conductor Resistance at 20℃ (max)
Nominal Area No. & Dia. of wire Nominal Thickness Nominal Core Dia. Nominal Thickness Approx. Overall Dia
1.5 22/0.30 0.8 3.25 1.5 10 12.1
2.5 36/0.30 0.9 3.84 1.5 11 7.41
4 56/0.30 1 4.5 1.6 13 4.95
6 85/0.30 1 5.3 1.6 14.6 3.3
10 140/0.30 1 6.5 2 18 1.91
16 226/0.30 1 8 2 21.2 1.21
25 354/0.30 1.2 10.1 2.15 26 0.78
35 495/0.30 1.2 11.3 2.15 28.3 0.554
50 703/0.30 1.4 13.6 2.25 33.5 0.386
70 440/0.45 1.4 15.3 2.45 37.8 0.272
95 475/0.50 1.6 18 2.4 43.5 0.206
Read More
FB_IMG_1588031161476

2.5mm 4mm 6mm flexible copper dc cable for submersible pumping system application

FEATURES & PROPERTIES :

Meets the requirement: VDE 0282 PART 810,     IEC 245, CEI 20-19 & BS 6007, BS 6899.

Designed for heavy duty use.

Cur, tear & abrasion resistant.

Exceptional long term performance.

Excellent resistant to oils, chemicals,ozone & solvents.

Excellent Impact Resistant.

Excellent Weather Resistant.

Performs & Looks like Vulcanize Rubber.

Excellent Electrical Properties.

APPLICATION :

For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.

 

CONSTRUCTION :

Conductor : Finely stranded bare copper flexible conductor.

Insulation : Oil & water resistant thermoplastic rubber,

Sheath : Black heavy duty thermoplastic rubber.

Core Colours :

4core: Red , Yellow Blue, Green Or Black

core: Black, Light Blue, Brown, Yellow with green line Or Green with yellow line

 

4CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)
Conductor  Insulation Sheath Conductor Resistance at 20℃ (max)
Nominal Area No. & Dia. of wire Nominal Thickness Nominal Core Dia. Nominal Thickness Approx. Overall Dia
1.5 22/0.30 0.8 3.25 1.5 10.8 12.1
2.5 36/0.30 0.9 3.84 1.65 12.5 7.41
4 56/0.30 1 4.5 1.65 14.1 4.95
6 85/0.30 1 5.3 1.65 16 3.3
10 140/0.30 1 6.5 2 20.35 1.91
16 226/0.30 1 8 2 23.4 1.21
25 354/0.30 1.2 10.1 2.2 28.8 0.78
35 495/0.30 1.2 11.5 2.2 31.5 0.554
50 703/0.30 1.4 13.6 2.3 37.3 0.386
70 440/0.30 1.4 15.3 2.6 42.2 0.272
95 475/0.50 1.6 18 2.65 48.8 0.206
Read More
2753604734_813241073

3 core or 4 core flat copper flexible electrical cable for water submersible pump

 

submersible pump cables are used as supply and control cables for engines for submersible pumps, underwater lighting, and floating switches etc. up to the depth of 500 m and water temperature up to +75°C. These cables are ideal for outer installations in dry, moist and wet environments but however not suitable for explosive areas.

Standard length cable packing:

Coils 100, 200,300 and 500, 1000m. in wooden reels

 

 

PVC Flat – 3 core
Conductor  Insulation  Sheath Current

Rating at

40℃

Nominal Area No. & Dia. of wire Nominal Thickness Nominal

Core Dia.

Nominal Thickness Approx. Overall

Dimensions

Thickness Width
mm2 No./mm mm mm mm mm mm Amps.
1.5 22/0.30 0.8 3.25 1.15 6 12.8 14
2.5 36/0.30 0.9 3.84 1.15 6.4 14.6 18
4 56/0.30 1 4.5 1.15 7.4 16.8 26
6 84/0.30 1 5.3 1.15 7.9 18.7 31
10 140/0.30 1 6.5 1.4 9.9 23.7 42
16 224/0.30 1 8 1.4 11.4 28 57
25 350/0.30 1.2 10.1 2 14.7 35.5 72
35 490/0.30 1.2 11.3 2 16.2 39.5 90
50 703/0.30 1.4 13.6 2.2 18.3 45.5 115
70 988/0.30 1.4 15.3 2.2 20 51 143
95 1349/0.30 1.6 18 2.4 23.5 60 165
Read More
20160923124647

Flat submersible 600 V pump cable/ deep well submersible pumps cable

Application:
For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.
Submersible Pump cables is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Jainson is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability
Feature :
Designed for heavy duty use.
Cur, tear & abrasion resistant.
Exceptional long term performance.
Excellent resistant to oils, chemicals, ozone & solvents.
Excellent Impact Resistant.
Excellent Weather Resistant.
Performs & Looks like Vulcanize Rubber.
Excellent Electrical Properties.
Temperature range -40° to +90°
Standards:DIN VDE 0282 PART 810, IEC 245,BS 6007, BS 6899.
Construction:
Conductor:Plain annealed flexible copper
Insulation:EPR
Sheath/Jacket:PCP Or Synthetic Rubber (Oil resistant & flame retardant)
Core Colours:
3core:Brown, Blue & Green / Yellow
4core:Brown, Blue, Black & Green / Yellow
FLAT CABLE USED FOR SUBMERSIBLE PUMPS IN boreholes
Conductor  Insulation  Sheath Current

Rating at 40℃

Nominal Area No. &

Dia. of wire

Nominal Thickness Nominal

Core Dia.

Nominal

Thickness

Approx. Overall

Dimensions

Thickness Width
mm2 No./mm mm mm mm mm mm Amps.
1.5 22/0.30 0.8 3.25 1.3 6 15.8 14
2.5 36/0.30 0.9 3.84 1.3 6.5 18 18
4 56/0.30 1 4.5 1.45 7.6 21 26
6 84/0.30 1 5.3 1.5 7.9 24.3 31
10 140/0.30 1 6.5 1.8 9.9 29.7 42
16 224/0.30 1 8 1.95 11.8 36 57
25 350/0.30 1.2 10.1 2 14.7 45.1 72
35 490/0.30 1.2 11.5 2 16.2 50.1 90
50 703/0.30 1.4 13.6 2.2 18.3 58.1 115
70 988/0.30 1.4 15.3 2.2 20 66.5 143
95 1349/0.30 1.6 18 2.4 23.5 77.3 165

 

 

Read More