PV Solar Panel MC4 Connection Extension Cable For Solar System

solar cable specifications
Core Conductor: Tinned annealed copper(stranded core)
Popular Sizes: 1×2.5mm2,1x4mm2,1x6mm2,1x10mm2 2×2.5mm2,2x4mm2,2x6mm2,2x10mm2
Cable Conductor: Stranded tinned annealed copper
Insulation: XLPE
Jacket: XLPE(black, red)
Nominal Volvatage: Uo/U= 600/1000VAC, 1000/1800VDC
Test Voltage: 6500V, 50HZ, 5Min
Fire Performance: IEC 60332-1, UL1581 VW-1
Bending Radius Fixed installation>4X,   Occasionally moved>5X

 

Single-Core Solar Cable
Cable  Size  (mm2)  Conductor  Strand              (mm) Nominal                   insulation             thickness                (mm) Nominal sheath thickness   (mm) Overall  Dia  (mm) Approx. Weight (kg/km) Max. Conductor Resis(20ºC)  (Ω/Km)
 1×4  56/0.30 0.8 0.8  5.8±0.3 68 4.95
 1×6  84/0.30 0.8 0.9  6.6±0.3 94 3.3

 

 

Read More
90

4MM2 6MM2 Solar Extension Cable With solar PV MC4 Connectors Male Female

Cable design

Conductor: fine wire strands of tinned copper wires,according IEC 60228,Class 5

Insulation: irradiation cross-linkable LSZH flame retardant polyolefin compound

Outer jacket: irradiation cross-linkable LSZH flame retardant polyolefin compound resistance against water , UV resistant

 

Temperature range

Max,temperature at conductor  -40°C up to +120°C

Temperature range  -40°C up to +90°C

Electrical characteristics

Nominal voltage: AC 600/1000V,DC 900/1800V

AC-test-voltage:  6.5KV

Application

SOLAR CABLE used for interconnection wiring of grounded and ungrounded photovoltaic power systems

 

Solar Cable
Size (AWG) Conductor   

Strand                                   (mm)

600V Cable OD (mm) 1000V & 2000V Cable OD                      (mm) Max DC Resistance   (20°C)  (Ω/km)
12 65/0.254 5.4 6.2 5.64
10 105/0.254 6.2 6.9 3.546
8 168/0.254 7.9 8.4 2.23
6 266/0.254 9.8 10.3 1.403
4 420/0.254 11.7 11.7 0.882
2 665/0.254 13.3 13.4 0.5548
1 836/0.254 15.2 16.1 0.4398

 

 

Read More
91

Solar Extension Cable With MC4 Connectors Male Female

solar cable specifications
Core Conductor: Tinned annealed copper(stranded core)
Popular Sizes:  1×2.5mm2,1x4mm2,1x6mm2,1x10mm2 2×2.5mm2,2x4mm2,2x6mm2,2x10mm2
Cable Conductor: Stranded tinned annealed copper
Insulation: XLPE
Jacket: XLPE(black, red)
Nominal Volvatage: Uo/U= 600/1000VAC, 1000/1800VDC
Test Voltage: 6500V, 50HZ, 5Min
Fire Performance: IEC 60332-1, UL1581 VW-1
Bending Radius Fixed installation>4X,   Occasionally moved>5X

 

Single-Core Solar Cable
Cable  Size  (mm2)  Conductor  Strand               (mm) Nominal insulation thickness                         (mm) Nominal sheath thickness   (mm) Overall  Dia               (mm) Approx. Weight (kg/km) Max. Conductor Resis(20ºC)  (Ω/Km)
 1×4  56/0.30 0.8 0.8  5.8±0.3 68 4.95
 1×6  84/0.30 0.8 0.9  6.6±0.3 94 3.3

 

 

 

Read More
solar tool08

EN50618 1500V dc solar cable extension cable with MC4 Connectors customized length

Application:

For the cabling between the solar modules and as extension cable between the module strings and the DC/AC inverter

Standard:

Cross-linked solar cables – type H1Z2Z2-K, certified according to EN 50618

 

Product features:

Flame retardant,Weather/UV-resistant,Ozone-resistant,Good notch and abrasion resistance

Cable Construction:

Conductor : Fine Wire Tinned Copper Conductor according to BS EN 50618 cl. 5.

Insulation : UV resistant, cross linkable, halogen free, flame retardant compound for core insulation.

Core Identification : Red, black or natural

Sheath : UV resistant, cross linkable, halogen free, flame retardant compound for Sheath over insulation.

Cable Colour : Black or Red,Blue

 

Benefits:

1.Reduction of flame propagation and of toxic combustion gases in the event of fire

2.Robust against mechanical impacts

3.For outdoor applications

4.Service Life: Expected life span ≥25 years

Single-Core Solar Cable
Cable  Size  (mm2)  Conductor  Strand                (mm) Nominal                  insulation                     thickness    (mm) Nominal sheath thickness   (mm) Overall  Dia       (mm) Approx.             Weight (kg/km) Max. Conductor Resis(20ºC)  (Ω/Km)
 1×4  56/0.30 0.8 0.8  5.8±0.3 68 4.95
 1×6  84/0.30 0.8 0.9  6.6±0.3 94 3.3

 

Read More